The ad4130 driver exports in_voltageY-voltageZ_filter_mode and
in_voltage-voltage_filter_mode_available attributes to user space. A
previous patch merged the documentation for those attributes with the
documentation for filter_type/filter_type_available into sysfs-bus-iio.
Filter mode and filter type refer to the same feature which is the digital
filter applied over ADC samples. However, since datasheets use the term
`filter type` and ad4130 driver is the only one using filter_mode,
deprecate the filter_mode ABI in favor of filter_type and keep the docs
separate to avoid confusion and intricate attribute descriptions.
Fixes: 01bb12922b ("Documentation: ABI: added filter mode doc in sysfs-bus-iio")
Signed-off-by: Marcelo Schmitt <marcelo.schmitt@analog.com>
Reviewed-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/c77b2d65f1115c1c394582f55944d6f685058f9c.1738680728.git.marcelo.schmitt@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
If one or more of the 16 channels are enabled and the driver is not
aware of that, unexpected things happen because different channels are
used than intended. To prevent that, all channels should be disabled at
probe time. In Commit 4be339af33 ("iio: adc: ad7124: Disable all
channels at probe time") I intended do that, however only the channels
that are potentially used by the driver and not all channels are
disabled since then. So disable all 16 channels and not only the used
ones.
Also fix the same issue in the .disable_all() callback.
Fixes: 4be339af33 ("iio: adc: ad7124: Disable all channels at probe time")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/20250204115023.265813-2-u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The current scale is not ABI-compliant as it is just the sensor gain
instead of the value that acts as a multiplier to be applied to the raw
value (there is no offset).
Use the iio-gts helpers to obtain the proper scale values according to
the gain and integration time to match the resolution tables from the
datasheet and drop dedicated variables to store the current values of
the integration time, gain and resolution. When at it, use 'scale'
instead of 'gain' consistently for the get/set functions to avoid
misunderstandings.
Fixes: 7b779f573c ("iio: light: add driver for veml6030 ambient light sensor")
Acked-by: Matti Vaittinen <mazziesaccount@gmail.com>
Signed-off-by: Javier Carrasco <javier.carrasco.cruz@gmail.com>
Link: https://patch.msgid.link/20250127-veml6030-scale-v3-2-4f32ba03df94@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The key objective in ad7124_disable_one() is clearing the
AD7124_CHANNEL_EN_MSK bit in the channel register. However there is no
advantage to keep the other bits in that register because when the
channel is used next time, all fields are rewritten anyhow. So instead
of using ad7124_spi_write_mask() (which is a register read plus a
register write) use a simple register write clearing the complete
register.
Also do the same in the .disable_all() callback by using the
.disable_one() callback there.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Reviewed-by: Nuno Sa <nuno.sa@analog.com>
Link: https://patch.msgid.link/20250120140708.1093655-2-u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
For debugging, add tracing for EC_CMD_MOTION_SENSE_CMD command:
- decode the name of the subcommand
- provide internal information for the most common sub-commands:
setting range, frequency, EC probing frequency, ...
- display return status.
When enabled, the tracing output is similar to:
/sys/kernel/debug/tracing # echo 1 > events/cros_ec/enable ; echo 1 > tracing_on ; cat trace_pipe | grep MOTIONSENSE_CMD_SENSOR_ODR
SensorDeviceImp-814 [003] ..... 686.176782: cros_ec_motion_host_cmd: MOTIONSENSE_CMD_SENSOR_ODR, id: 1, data: 200000, result: 4, return: 12500
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-by: Tzung-Bi Shih <tzungbi@kernel.org>
Link: https://patch.msgid.link/20250121232007.1020666-1-gwendal@chromium.org
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Use "instruction" mode over initial configuration and all other
non-streaming operations.
DAC boots in streaming mode as default, and the driver is not
changing this mode.
Instruction r/w is still working because instruction is processed
from the DAC after chip select is deasserted, this works until
loop mode is 0 or greater than the instruction size.
All initial operations should be more safely done in instruction
mode, a mode provided for this.
Signed-off-by: Angelo Dureghello <adureghello@baylibre.com>
Link: https://patch.msgid.link/20250114-wip-bl-ad3552r-axi-v0-iio-testing-carlos-v4-6-979402e33545@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad354xr requires DSPI mode (2 data lanes) to work in buffering
mode, so, depending on the DAC type, target TRANSFER_REGISTER
"MULTI_IO_MODE" bitfield can be set between:
SPI (configuration, entire ad35xxr family),
DSPI (ad354xr),
QSPI (ad355xr).
Also bus IO_MODE must be set accordingly.
About removal of AXI_DAC_CUSTOM_CTRL_SYNCED_TRANSFER, according to
the HDL history the flag has never been used. So looks like the driver
was including it by mistake or in anticipation for something that was
never implemented on HDL side.
Current HDL updated documentation confirm it is actually not in use
anymore and replaced by the IO_MODE bits.
Reviewed-by: Nuno Sa <nuno.sa@analog.com>
Signed-off-by: Angelo Dureghello <adureghello@baylibre.com>
Link: https://patch.msgid.link/20250114-wip-bl-ad3552r-axi-v0-iio-testing-carlos-v4-4-979402e33545@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Make available scale building more clear. This hurts the performance
quite a bit by looping throgh the scales many times instead of doing
everything in one loop. It however simplifies logic by:
- decoupling the gain and scale allocations & computations
- keeping the temporary 'per_time_gains' table inside the
per_time_scales computation function.
- separating building the 'all scales' table in own function and doing
it based on the already computed per-time scales.
Signed-off-by: Matti Vaittinen <mazziesaccount@gmail.com>
Tested-by: subhajit.ghosh@tweaklogic.com
Link: https://patch.msgid.link/Z1_rRXqdhxhL6wBw@mva-rohm
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Ensure that conversion mode is successfully exited when the command is
issued by adding an extra transfer beforehand, matching the minimum CNV
high and low times from the AD4695 datasheet. The AD4695 has a quirk
where the exit command only works during a conversion, so guarantee this
happens by triggering a conversion in ad4695_exit_conversion_mode().
Then make this even more robust by ensuring that the exit command is run
at AD4695_REG_ACCESS_SCLK_HZ rather than the bus maximum.
Signed-off-by: Trevor Gamblin <tgamblin@baylibre.com>
Reviewed-by: David Lechner <dlechner@baylibre.com>
Tested-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20241113-tgamblin-ad4695_improvements-v2-2-b6bb7c758fc4@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Replace ternary (condition ? "enable" : "disable") syntax with helpers
from string_choices.h because:
1. Simple function call with one argument is easier to read. Ternary
operator has three arguments and with wrapping might lead to quite
long code.
2. Is slightly shorter thus also easier to read.
3. It brings uniformity in the text - same string.
4. Allows deduping by the linker, which results in a smaller binary
file.
Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://patch.msgid.link/20250114192716.912476-1-krzysztof.kozlowski@linaro.org
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Move the call to fwnode_irq_get_byname() from the driver-specific
ad7173_fw_parse_device_config() to the shared ad_sd_init() function.
The main reason for this is that we want struct ad_sigma_delta_info to
be static const data that describes the actual ADC chip, not the
application-specific configuration or any runtime state.
Previously, this struct was being used to pass the IRQ number to the
shared ad_sd_init() function. Now, this is replaced by a boolean flag
that is set at compile time and the ad_sd_init() function handles
looking up the IRQ number instead. This also has the added benefit that
if any other drivers need to make use of this in the future, they just
have to set the flag and the shared code will take care of the rest
rather than duplicating the code in each driver.
Signed-off-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20250113-iio-adc-ad7313-fix-non-const-info-struct-v4-1-b63be3ecac4a@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The alert functionality is an out of range indicator and can be used as
an early indicator of an out of bounds conversion result.
ALERT_LOW_THRESHOLD and ALERT_HIGH_THRESHOLD registers are common to all
channels.
When using 1 SDO line (only mode supported by the driver right now), i.e
data outputs only on SDOA, SDOB (or SDOD for 4 channels variants) is
used as an alert pin. The alert pin is updated at the end of the
conversion (set to low if an alert occurs) and is cleared on a falling
edge of CS.
The ALERT register contains information about the exact alert status:
channel and direction. ALERT register can be accessed using debugfs if
enabled.
User can set high/low thresholds and enable alert detection using the
regular iio events attributes:
events/in_thresh_falling_value events/in_thresh_rising_value
events/thresh_either_en
In most use cases, user will hardwire the alert pin to trigger a shutdown.
In theory, we could generate userspace IIO events for alerts, but this
is not implemented yet for several reasons [1]. This can be implemented
later if a real use case actually requires it.
Signed-off-by: Julien Stephan <jstephan@baylibre.com>
[1] https://lore.kernel.org/all/4be16272-5197-4fa1-918c-c4cdfcaee02e@baylibre.com/
Reviewed-by: David Lechner <dlechner@baylibre.com>
Link: https://patch.msgid.link/20250108-ad7380-add-alert-support-v4-4-1751802471ba@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>