PF1550 starts in charger mode 1, where charging is disabled. The driver
comment says that mode 2 should be selected for applications using a
battery, but the condition is inverted: PF1550_CHG_BAT_ON is written only
when power_supply_get_battery_info() fails.
Consequently, a board with a valid monitored-battery profile is left in
the default charger-off mode, while a board without battery information
enables charging with fallback settings.
Select mode 2 when battery information is available.
Fixes: 4b6b6433a9 ("power: supply: pf1550: add battery charger support")
Cc: stable@vger.kernel.org
Signed-off-by: Xu Rao <raoxu@uniontech.com>
Reviewed-by: Frank Li <Frank.Li@nxp.com>
Link: https://patch.msgid.link/097F0559A936ACCB+20260724095437.368905-1-raoxu@uniontech.com
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>