Dimitri Fedrau dea750f801 iio: temperature: mcp9600: add threshold events support
The device has four programmable temperature alert outputs which can be
used to monitor hot or cold-junction temperatures and detect falling and
rising temperatures. It supports up to 255 degree celsius programmable
hysteresis. Each alert can be individually configured by setting following
options in the associated alert configuration register:
- monitor hot or cold junction temperature
- monitor rising or falling temperature
- set comparator or interrupt mode
- set output polarity
- enable alert

This patch binds alert outputs to iio events:
- alert1: hot junction, rising temperature
- alert2: hot junction, falling temperature
- alert3: cold junction, rising temperature
- alert4: cold junction, falling temperature

All outputs are set in comparator mode and polarity depends on interrupt
configuration.

Signed-off-by: Dimitri Fedrau <dima.fedrau@gmail.com>
Link: https://lore.kernel.org/r/20240604133639.959682-1-dima.fedrau@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
2024-06-13 19:19:25 +01:00
2022-09-28 09:02:20 +02:00
2024-05-26 15:20:12 -07:00
2024-03-18 03:36:32 -06:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the reStructuredText markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.4 GiB
Languages
C 97%
Assembly 1%
Shell 0.6%
Rust 0.5%
Python 0.4%
Other 0.3%