Pierre-Louis Bossart 88d7c71ea5 soundwire: bus: update multi-link definition with hw sync details
Hardware-based synchronization is typically required when the
bus->multi_link flag is set.

On Intel platforms, when the Cadence IP is configured in 'Multi Master
Mode', the hardware synchronization is required even when a stream
only uses a single segment. The existing code only deal with hardware
synchronization when a stream uses more than one segment so to remain
backwards compatible we add a configuration threshold. For Intel cases
this threshold will be set to one, other platforms may be able to use
the SSP-based sync in those cases.

Signed-off-by: Pierre-Louis Bossart <pierre-louis.bossart@linux.intel.com>
Signed-off-by: Bard Liao <yung-chuan.liao@linux.intel.com>
Link: https://lore.kernel.org/r/20200901150556.19432-6-yung-chuan.liao@linux.intel.com
Signed-off-by: Vinod Koul <vkoul@kernel.org>
2020-09-03 16:14:39 +05:30
2020-08-14 19:56:56 -07:00
2020-08-16 13:04:57 -07:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.5 GiB
Languages
C 97.1%
Assembly 1%
Shell 0.6%
Rust 0.4%
Python 0.4%
Other 0.3%