Daniel Kurtz 7fcef92db8 arm64: dts: mt8173: Fix cpu_thermal cooling-maps contributions
According to [0], the contribution field for each cooling-device express
their relative power efficiency. Higher weights express higher power
efficiency.  Weighting is relative such that if each cooling device has a
weight of 1 they are considered equal. This is particularly useful in
heterogeneous systems where two cooling devices may perform the same kind
of compute, but with different efficiency.

[0] Documentation/thermal/power_allocator.txt

According to Mediatek IC designer, the power efficiency ratio between the
LITTLE core cluster (cooling-device cpu0) and big core cluster
(cooling-device cpu1) is around 3:1 (3072:1024).

Signed-off-by: Daniel Kurtz <djkurtz@chromium.org>
Signed-off-by: Matthias Brugger <matthias.bgg@gmail.com>
2017-01-13 16:35:55 +01:00
2016-12-25 17:21:22 +01:00
2016-12-25 17:21:23 +01:00
2016-12-25 17:21:23 +01:00
2016-12-25 17:21:22 +01:00
2016-05-23 17:04:14 -07:00
2016-12-25 16:13:08 -08:00

Linux kernel
============

This file was moved to Documentation/admin-guide/README.rst

Please notice that there are several guides for kernel developers and users.
These guides can be rendered in a number of formats, like HTML and PDF.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.
See Documentation/00-INDEX for a list of what is contained in each file.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.6 GiB
Languages
C 97%
Assembly 1%
Shell 0.6%
Rust 0.5%
Python 0.4%
Other 0.3%