Viresh Kumar 4d8aa0097d ARM: dts: ls1021a: Add all CPUs in cooling maps
Each CPU can (and does) participate in cooling down the system but the
DT only captures a handful of them, normally CPU0, in the cooling maps.
Things work by chance currently as under normal circumstances its the
first CPU of each cluster which is used by the operating systems to
probe the cooling devices. But as soon as this CPU ordering changes and
any other CPU is used to bring up the cooling device, we will start
seeing failures.

Also the DT is rather incomplete when we list only one CPU in the
cooling maps, as the hardware doesn't have any such limitations.

Update cooling maps to include all devices affected by individual trip
points.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Shawn Guo <shawnguo@kernel.org>
2018-12-10 10:02:24 +08:00
2018-10-31 08:54:14 -07:00
2018-10-31 08:54:12 -07:00
2018-11-04 15:37:52 -08:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.4 GiB
Languages
C 97%
Assembly 1%
Shell 0.6%
Rust 0.5%
Python 0.4%
Other 0.3%