Uwe Kleine-König 486dd4e846 pwm: ab8500: Fix calculation of duty and period
After a check of the manual it becomes obvious that the calculations in
.apply() are totally bogus:

FreqPWMOutx was always written as zero, so the period was fixed at
3413333.33 ns. However state->period wasn't checked at all.
The lower 10 bits of duty_cycle were just used as DutyPWMOutx. So if
a duty cycle of 512 ns (or 1536 ns) was requested, it actually
programmed 1710000 ns. Other values were wrong by the same factor.

Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
2023-02-17 15:59:51 +01:00
2022-12-04 01:59:16 +01:00
2022-09-28 09:02:20 +02:00
2022-12-25 13:41:39 -08:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.