Alexey Kardashevskiy 11f5acce2f powerpc/powernv/ioda: Fix locked_vm counting for memory used by IOMMU tables
We store 2 multilevel tables in iommu_table - one for the hardware and
one with the corresponding userspace addresses. Before allocating
the tables, the iommu_table_group_ops::get_table_size() hook returns
the combined size of the two and VFIO SPAPR TCE IOMMU driver adjusts
the locked_vm counter correctly. When the table is actually allocated,
the amount of allocated memory is stored in iommu_table::it_allocated_size
and used to decrement the locked_vm counter when we release the memory
used by the table; .get_table_size() and .create_table() calculate it
independently but the result is expected to be the same.

However the allocator does not add the userspace table size to
.it_allocated_size so when we destroy the table because of VFIO PCI
unplug (i.e. VFIO container is gone but the userspace keeps running),
we decrement locked_vm by just a half of size of memory we are
releasing.

To make things worse, since we enabled on-demand allocation of
indirect levels, it_allocated_size contains only the amount of memory
actually allocated at the table creation time which can just be a
fraction. It is not a problem with incrementing locked_vm (as
get_table_size() value is used) but it is with decrementing.

As the result, we leak locked_vm and may not be able to allocate more
IOMMU tables after few iterations of hotplug/unplug.

This sets it_allocated_size in the pnv_pci_ioda2_ops::create_table()
hook to what pnv_pci_ioda2_get_table_size() returns so from now on we
have a single place which calculates the maximum memory a table can
occupy. The original meaning of it_allocated_size is somewhat lost now
though.

We do not ditch it_allocated_size whatsoever here and we do not call
get_table_size() from vfio_iommu_spapr_tce.c when decrementing
locked_vm as we may have multiple IOMMU groups per container and even
though they all are supposed to have the same get_table_size()
implementation, there is a small chance for failure or confusion.

Fixes: 090bad39b2 ("powerpc/powernv: Add indirect levels to it_userspace")
Signed-off-by: Alexey Kardashevskiy <aik@ozlabs.ru>
Reviewed-by: David Gibson <david@gibson.dropbear.id.au>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
2019-02-28 11:50:02 +11:00
2018-10-31 08:54:14 -07:00
2019-02-21 23:15:10 +11:00
2019-01-08 07:45:01 +01:00
2019-01-04 14:27:09 -07:00
2019-01-14 10:41:12 +12:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.5 GiB
Languages
C 97.1%
Assembly 1%
Shell 0.6%
Rust 0.4%
Python 0.4%
Other 0.3%