Colin Ian King 0e7c353e18 scsi: pm80xx: fix logic to break out of loop when register value is 2 or 3
The condition (reg_val != 2) || (reg_val != 3) will always be true because
reg_val cannot be equal to two different values at the same time. Fix this
by replacing the || operator with && so that the loop will loop if reg_val
is not a 2 and not a 3 as was originally intended.

Fixes: 50dc2f221455 ("scsi: pm80xx: Modified the logic to collect fatal dump")
Link: https://lore.kernel.org/r/20191120135031.270708-1-colin.king@canonical.com
Addresses-Coverity: ("Constant expression result")
Signed-off-by: Colin Ian King <colin.king@canonical.com>
Acked-by: Jack Wang <jinpu.wang@cloud.ionos.com>
Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
2019-11-26 21:30:12 -05:00
2019-09-13 17:21:38 +03:00
2019-09-30 10:35:40 -07:00

Linux kernel
============

There are several guides for kernel developers and users. These guides can
be rendered in a number of formats, like HTML and PDF. Please read
Documentation/admin-guide/README.rst first.

In order to build the documentation, use ``make htmldocs`` or
``make pdfdocs``.  The formatted documentation can also be read online at:

    https://www.kernel.org/doc/html/latest/

There are various text files in the Documentation/ subdirectory,
several of them using the Restructured Text markup notation.

Please read the Documentation/process/changes.rst file, as it contains the
requirements for building and running the kernel, and information about
the problems which may result by upgrading your kernel.
Description
No description provided
Readme 3.4 GiB
Languages
C 97%
Assembly 1%
Shell 0.6%
Rust 0.5%
Python 0.4%
Other 0.3%