Alex Elder 03130a77d5 greybus: fix op_cycle logic
The function that computes the operation id for a connection is
wrongly using MOD rather than AND.  Fix that.

Signed-off-by: Alex Elder <elder@linaro.org>
Signed-off-by: Greg Kroah-Hartman <greg@kroah.com>
2014-10-21 14:36:11 +08:00