Add support for STM32MP25 SoC. Use newly introduced compatible to handle
this new HW variant. Add TIM20 trigger definitions that can be used by
the stm32 analog-to-digital converter. Use compatible data to identify
it.
As the counter framework is now superseding the deprecated IIO counter
interface (IIO_COUNT), don't support it. Only register IIO trigger
devices for ADC usage. So, make the valids_table a cfg option.
Signed-off-by: Fabrice Gasnier <fabrice.gasnier@foss.st.com>
Link: https://patch.msgid.link/20241220095927.1122782-4-fabrice.gasnier@foss.st.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ROHM BD79703 is a 6 channel digital to analog converter.
Based on the data-sheet examples the hardware would support setting the
DAC word without changing the actual output. The data-sheet is not too
specific on how the enabling the output of new voltage set by DAC
should be done - hence this is not implemented by the driver.
The BD79703 would also support two specific "PULL_DOWN" modes. These
aren't currently supported by the driver either.
Add a very basic support for controlling the channel outputs one-by-one.
Signed-off-by: Matti Vaittinen <mazziesaccount@gmail.com>
Link: https://patch.msgid.link/bc77d7b979ca28408a216f597082fcd94ec63be7.1734608215.git.mazziesaccount@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Since there are no more direct accesses to the indio_dev->scan_timestamp
value, it can be marked as __private and use the macro ACCESS_PRIVATE()
in order to access it. Like this, static checkers will be able to inform
in case someone tries to either write to the value, or read its value
directly.
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://patch.msgid.link/20241214191421.94172-5-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Drop the recurrent allocation of the data buffer from the trigger
handler and put it in the iio_priv(). This way, the maximum amount of
channels is always allocated in favor of simpler code and drop
of usage of the internal private variable "scan_timestamp" of the
struct iio_dev.
Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Link: https://patch.msgid.link/20241214191421.94172-3-vassilisamir@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad7173 family of chips has up to four calibration modes.
Internal zero scale: removes ADC core offset errors.
Internal full scale: removes ADC core gain errors.
System zero scale: reduces offset error to the order of channel noise.
System full scale: reduces gain error to the order of channel noise.
All voltage channels will undergo an internal zero/full scale
calibration at bootup.
System zero/full scale can be done after bootup using the newly created
iio interface 'sys_calibration' and 'sys_calibration_mode'
Signed-off-by: Guillaume Ranquet <granquet@baylibre.com>
Link: https://patch.msgid.link/20241202-ad411x_calibration-v3-1-beb6aeec39e2@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ADI PulSAR series of single-channel devices comprises differential and
pseudo-differential ADCs that don't require any input data from the host
controller. By not requiring a data input line, PulSAR devices can operate
with a 3-wire only data bus in some setups.
The AD4000 series and the single-channel PulSAR series of devices have
similar SPI transfer specifications and wiring configurations.
Single-channel PulSAR devices are slower than AD4000 and don't have a
configuration register. That taken into account, single-channel PulSARs can
be supported by the ad4000 driver without any increase in code complexity.
Extend the AD4000 driver to also support single-channel PulSAR devices.
Reviewed-by: David Lechner <dlechner@baylibre.com>
Signed-off-by: Marcelo Schmitt <marcelo.schmitt@analog.com>
Link: https://patch.msgid.link/2bfb904e29914c3dc4905e1c87fcc735575f330d.1733147444.git.marcelo.schmitt@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Extend the AD4000 series device tree documentation to also describe
PulSAR devices.
The single-channel series of PulSAR devices is similar to the AD4000 series
except PulSAR devices sample at slower rates and don't have a
configuration register. Because PulSAR devices don't have a configuration
register, they don't support all features of AD4000 devices and thus fewer
interfaces are provided to user space. Also, while AD4000 may have their
SDI pin connected to SPI host MOSI line, PulSAR SDI pin is never connected
to MOSI.
Some devices within the PulSAR series are just faster versions of others.
>From fastest to slowest, AD7980, AD7988-5, AD7686, AD7685, and AD7988-1 are
all 16-bit pseudo-differential pin-for-pin compatible ADCs. Devices that
only vary on the sample rate are documented with a common fallback
compatible.
Signed-off-by: Marcelo Schmitt <marcelo.schmitt@analog.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org>
Link: https://patch.msgid.link/cc05f1471c409ab38722cd0e80fd5857ff9ce5db.1733147444.git.marcelo.schmitt@analog.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Attributes of iio providers are exposed via sysfs. Typically, providers
pass attribute values to the iio core, which handles formatting and
printing to sysfs. However, some attributes, such as labels or extended
info, are directly formatted and printed to sysfs by provider drivers
using sysfs_emit() and sysfs_emit_at(). These helpers assume the read
buffer, allocated by sysfs fop, is page-aligned. When these attributes
are accessed by consumer drivers, the read buffer is allocated by the
consumer and may not be page-aligned, leading to failures in the
provider's callback that utilizes sysfs_emit*.
Add a check to ensure that read buffers for labels and external info
attributes are page-aligned. Update the prototype documentation as well.
Signed-off-by: Matteo Martelli <matteomartelli3@gmail.com>
Link: https://patch.msgid.link/20241202-iio-kmalloc-align-v1-1-aa9568c03937@gmail.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This patch makes I2C, I3C and SPI interface drivers for ST lsm6dsx
individually selectable via Kconfig.
The default is kept unchanged - I2C, I3C and SPI interface drivers are
still selected by default if the corresponding bus support is available.
However, the patch makes it possible to explicitly disable drivers
that are not needed for a particular target.
Signed-off-by: Sean Nyekjaer <sean@geanix.com>
Link: https://patch.msgid.link/20241203-lsm6dsx-v1-1-6d7893443bc8@geanix.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The various chips can be reset using a sequence of SPI transfers with
MOSI = 1. The length of such a sequence varies from chip to chip. Store
that length in struct ad_sigma_delta_info and replace the respective
parameter to ad_sd_reset() with it.
Note the ad7192 used to pass 48 as length but the documentation
specifies 40 as the required length. Assuming the latter is right.
(Using a too long sequence doesn't hurt apart from using a longer spi
transfer than necessary, so this is no relevant fix.)
The motivation for storing this information is that this is useful to
clear a pending R̅D̅Y̅ signal in the next change.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/9750db62fce638bf140ff48172c23bff7f785e5b.1733504533.git.u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad_sigma_delta driver helper uses irq_disable_nosync(). With that
one it is possible that the irq handler still runs after the
irq_disable_nosync() function call returns. Also to properly synchronize
irq disabling in the different threads proper locking is needed and
because it's unclear if the irq handler's irq_disable_nosync() call
comes first or the one in the enabler's error path, all code locations
that disable the irq must check for .irq_dis first to ensure there is
exactly one disable call per enable call.
So add a spinlock to the struct ad_sigma_delta and use it to synchronize
irq enabling and disabling. Also only act in the irq handler if the irq
is still enabled.
Fixes: af3008485e ("iio:adc: Add common code for ADI Sigma Delta devices")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/9e6def47e2e773e0e15b7a2c29d22629b53d91b1.1733504533.git.u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
Some of the ADCs by Analog signal their irq condition on the MISO line.
So typically that line is connected to an SPI controller and a GPIO. The
GPIO is used as input and the respective interrupt is enabled when the
last SPI transfer is completed.
Depending on the GPIO controller the toggling MISO line might make the
interrupt pending even while it's masked. In that case the irq handler
is called immediately after irq_enable() and so before the device
actually pulls that line low which results in non-sense values being
reported to the upper layers.
The only way to find out if the line was actually pulled low is to read
the GPIO. (There is a flag in AD7124's status register that also signals
if an interrupt was asserted, but reading that register toggles the MISO
line and so might trigger another spurious interrupt.)
Add the possibility to specify an interrupt GPIO in the machine
description in addition to the plain interrupt. This GPIO is used then
to check if the irq line is actually active in the irq handler.
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/5be9a4cc4dc600ec384c88db01dd661a21506b9c.1733504533.git.u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
For the AD7124 chip and some of its cousins the logical irq line (R̅D̅Y̅)
is physically on the same pin as the spi MISO output (DOUT) and so
reading a register might trigger an interrupt. For correct operation
it's critical that the actual state of the pin can be read to judge if
an interrupt event is a real one or just a spurious one triggered by
toggling the line in its MISO mode.
Allow specification of an "rdy-gpios" property that references a GPIO
that can be used for that purpose. While this is typically the same GPIO
also used (implicitly) as interrupt source, it is still supposed that
the interrupt is specified as before and usual.
Acked-by: Conor Dooley <conor.dooley@microchip.com>
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/7fc92a8539e55802d514332e70ee836a3ed08b66.1733504533.git.u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
The ad7124-4 has 8 analog inputs; the input select values 8 to 15 are
reserved and not to be used. These are fine for ad7124-8. For both
ad7124-4 and ad7124-8 values bigger than 15 are internal channels that
might appear as inputs in the channels specified in the device
description according to the description of commit f1794fd7bd ("iio:
adc: ad7124: Remove input number limitation"), values bigger than 31
don't fit into the respective register bit field and the driver masked
them to smaller values.
Check for these invalid input specifiers and fail to probe if one is
found.
Fixes: f1794fd7bd ("iio: adc: ad7124: Remove input number limitation")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/80e3bd629d2b755ab5e061c8731dafa57d08698a.1733504533.git.u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>