Even if that's the same as IEEE80211_MAX_SSID_LEN, we really
should just use IEEE80211_MAX_MESH_ID_LEN for mesh, rather
than having the BUILD_BUG_ON()s.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This is set when a P2P ROC ends, and uses as an indication inside
iwl_mvm_roc_done_wk that the resources used for this ROC (sta/link)
needs to be flushed/deactivated (respectively).
But we also have IWL_MVM_STATUS_ROC_RUNNING, which is set whenever
P2P ROC starts, and is not even used in iwl_mvm_roc_done_wk.
Use IWL_MVM_STATUS_ROC_RUNNING as an indicator, and remove the redundant
bit.
While at it, add a call to synchronize_net also for the
AUX ROC case, which is missing in the existing code.
Signed-off-by: Miri Korenblit <miriam.rachel.korenblit@intel.com>
Link: https://msgid.link/20240205211151.0494f75de311.Ic4aacacf7581a5c9046c4f1df87cbb67470853e7@changeid
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
There's a conflict already and some upcoming changes
also depend on changes in wireless for being conflict-
free, so pull wireless in to make all that easier.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
In MFP, do not disconnect if an unprotected deauth
or disassoc was received during D3.
For that, need to configure wowlan with MFP (IS_11W_ASSOC).
Now, in case of an unprotected deauth/disassoc, the wakeup
reason returned by the firmware will be:
IWL_WAKEUP_BY_11W_UNPROTECTED_DEAUTH_OR_DISASSOC
(and not IWL_WOWLAN_WAKEUP_BY_DISCONNECTION_ON_DEAUTH
which will cause a disconnection).
Also, report this reason to cfg80211.
In another patch, the driver will send an SA query.
Signed-off-by: Shaul Triebitz <shaul.triebitz@intel.com>
Signed-off-by: Miri Korenblit <miriam.rachel.korenblit@intel.com>
Link: https://msgid.link/20240206175739.fde438a22e3f.I3c8497520aaa95a22febff727b0ad08146965d47@changeid
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
If the hardware supports a disabled channel, it may in
some cases be possible to use monitor mode (without any
transmit) on it when it's otherwise disabled. Add a new
channel flag IEEE80211_CHAN_CAN_MONITOR that makes it
possible for a driver to indicate such a thing.
Make it per channel so drivers could have a choice with
it, perhaps it's only possible on some channels, perhaps
some channels are not supported at all, but still there
and marked disabled.
In _nl80211_parse_chandef() simplify the code and check
only for an unknown channel, _cfg80211_chandef_usable()
will later check for IEEE80211_CHAN_DISABLED anyway.
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Signed-off-by: Miri Korenblit <miriam.rachel.korenblit@intel.com>
Link: https://msgid.link/20240206164849.87fad3a21a09.I9116b2fdc2e2c9fd59a9273a64db7fcb41fc0328@changeid
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Currently, whenever AP link is brought down via ieee80211_stop_ap()
function, all stations connected to the sdata are flushed. However, in case
of MLO there is a requirement to flush only stations connected to that link
and not all.
For instance - Consider 2 GHz and 5 GHz are AP MLD. Now due to some reason
5 GHz link of this AP is going down (link removal or any other case). All
stations connected, even legacy stations connected to 2 GHz link AP would
also be flushed. Flushing of other link stations is not desirable.
Fix this issue by passing self link ID to sta_flush() function. This would
then only remove the stations which are still using the passed link
ID as their link sta. Other stations will not be affected.
Signed-off-by: Aditya Kumar Singh <quic_adisi@quicinc.com>
Link: https://msgid.link/20240205162952.1697646-4-quic_adisi@quicinc.com
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Whenever sta_flush() function is invoked, all STAs present in that
interface are flushed. In case of MLO, it is desirable to only flush such
STAs that are at least using a given link id as one of their links.
Add support for this by making change in the __sta_info_flush API argument
to accept a link ID. And then, only if the STA is using the given link as
one of its links, it would be flushed.
Signed-off-by: Aditya Kumar Singh <quic_adisi@quicinc.com>
Link: https://msgid.link/20240205162952.1697646-3-quic_adisi@quicinc.com
[reword commit message, in particular this isn't about "active" links]
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Currently whenever NL80211_CMD_DEL_STATION command is called without any
MAC address, all stations present on that interface are flushed.
However with MLO there is a need to flush such stations only which are
using at least a particular link from the AP MLD interface.
For example - 2 GHz and 5 GHz are part of an AP MLD.
To this interface, following stations are connected -
1. One non-EHT STA on 2 GHz link.
2. One non-EHT STA on 5 GHz link.
3. One Multi-Link STA having 2 GHz and 5 GHz as active links.
Now if currently, NL80211_CMD_DEL_STATION is issued by the 2 GHz link
without any MAC address, it would flush all station entries. However,
flushing of station entry #2 at least is not desireable since it
is connected to 5 GHz link alone.
Hence, add an option to pass link ID as well in the command so that if link
ID is passed, stations using that passed link ID alone would be flushed
and others will not.
So after this, station entries #1 and #3 alone would be flushed and #2 will
remain as it is.
Signed-off-by: Aditya Kumar Singh <quic_adisi@quicinc.com>
Link: https://msgid.link/20240205162952.1697646-2-quic_adisi@quicinc.com
[clarify documentation]
Signed-off-by: Johannes Berg <johannes.berg@intel.com>
Since WiFi 7 is expected to support MLO, so we should enable MAC-0/1 and
PHY-0/1. By default, set dbcc_en=true, change quota to DBCC mode, and set
MLO mode to 2 + 0 that means we only use 2x2 connection on MAC/PHY-0
for now.
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240209065229.34515-12-pkshih@realtek.com
In 'brcmf_cfg80211_start_ap()', not assume that
NL80211_HIDDEN_SSID_NOT_IN_USE is zero but prefer
an explicit check instead. Compile tested only.
Found by Linux Verification Center (linuxtesting.org) with SVACE.
Signed-off-by: Alexey Berezhok <a@bayrepo.ru>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240208085121.2430-1-a@bayrepo.ru
Document
ATWILC1000/ATWILC3000
Baremetal Wi-Fi/BLE Link Controller Software Design Guide
https://tinyurl.com/yer2xhyc
says that bit 0 of the CRC7 code must always be a 1.
I confirmed that today with a logic analyzer: setting bit 0 causes
wilc1000 to accept a command with CRC7 enabled, whereas clearing bit 0
causes wilc1000 to reject the command with a CRC error.
Signed-off-by: David Mosberger-Tang <davidm@egauge.net>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240207050736.2717641-1-davidm@egauge.net
During mac80211 reconfig, chanctx ops of multiple channels might not
be called in order as normal cases. However, we expect the first active
chanctx always to be put at our sub entity index 0. So, if it does not,
we do a swap there. Besides, reconfig won't allocate a new chanctx object.
So, we should reset the reference count when ops add chanctx.
Signed-off-by: Zong-Zhe Yang <kevin_yang@realtek.com>
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240206030624.23382-7-pkshih@realtek.com
After MLO, we will need to consider not only active chanctx but also active
interfaces (roles) to decide entity things. So in advance, we move handling
from chanctx_ops::add/remove to chanctx_ops::assign_vif/unassign_vif. Then,
we can recalculate and aware active interfaces' changes.
For now, behavior should not be really different, since active chanctx and
active interface are one-to-one mapping before MLO.
Signed-off-by: Zong-Zhe Yang <kevin_yang@realtek.com>
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240206030624.23382-6-pkshih@realtek.com
Originally, we consider weight only based on how many chanctxs that
mac80211 sets. However, we need to consider both active chanctxs and
active interfaces to distinguish MCC (multiple channel concurrent)
from impending MLO.
Although the logic of handling is extended, for now, behavior might
not be different under current condition.
Signed-off-by: Zong-Zhe Yang <kevin_yang@realtek.com>
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240206030624.23382-5-pkshih@realtek.com
Originally, we just declared two sub-entity, and according to rolling
down mechanism, we ensured that index 0 contained sub-entity as long
as there are sub-entity. So, we could use for-loop after deciding the
last index.
But, we are preparing to expand num of sub-entity for MLO. Then, there
won't be just two sub-entity. And, there might be holes between two bits
in the bitmap. So, we cannot simply do for-loop as before. Instead, we
need to follow the set bits.
Signed-off-by: Zong-Zhe Yang <kevin_yang@realtek.com>
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240206030624.23382-4-pkshih@realtek.com
Some of our calculation during concurrent mode depend on last beacon
TSF. Originally, we just set IEEE80211_HW_TIMING_BEACON_ONLY and get
what we want from mac80211. But, IEEE80211_HW_TIMING_BEACON_ONLY will
be restricted once we declare MLO.
Since we are about to consider the MLO stuffs, so sync beacon TSF by
ourselves now and unset IEEE80211_HW_TIMING_BEACON_ONLY.
Signed-off-by: Zong-Zhe Yang <kevin_yang@realtek.com>
Signed-off-by: Ping-Ke Shih <pkshih@realtek.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240206030624.23382-2-pkshih@realtek.com
WILC driver currently applies some default configuration whenever the firmware
is initialized, and sets the default preamble size to short. However, despite
this passed option, firmware is also able to successfully connect to access
points only using long preamble, so this setting does not really enforce short
preambles and is misleading regarding applied configuration.
Update default configuration and make it match the firmware behavior by passing
the existing WILC_FW_PREAMBLE_AUTO value (2 instead of 0). The updated setting
does not really alter firmware behavior since it is still capable to connect to
both short preamble and long preamble access points, but at list the setting now
expresses for real the corresponding firmware behavior.
More info: it has been implemented to address the transmission (Tx) blackout
issue observed in the 802.11b mode. The modification has no impact on the other
modes, which will continue to work as they did in the previous implementation.
This change will allow the 802.11b transmission (2, 5.5, 11Mbps) to use long
preamble.
Signed-off-by: Ajay Singh <ajay.kathat@microchip.com>
Signed-off-by: Alexis Lothoré <alexis.lothore@bootlin.com>
Signed-off-by: Kalle Valo <kvalo@kernel.org>
Link: https://msgid.link/20240115-wilc_1000_fixes-v1-1-54d29463a738@bootlin.com