iio: adc: ad_sigma_delta: Disable channel after calibration

The function ad_sd_calibrate() enables the channel to calibrate at
function entry but doesn't disable it on exit. This is problematic
because if two (or more) channels are calibrated in a row, the second
calibration isn't executed as intended as the first (still enabled)
channel is recalibrated and after the first irq (i.e. when the
calibration of the first channel completed) the calibration is aborted.

This currently affects ad7173 only, as the other drivers using
ad_sd_calibrate() never have more than one channel enabled at a time.

To fix this, disable the calibrated channel after calibration.

Fixes: 031bdc8aee ("iio: adc: ad7173: add calibration support")
Signed-off-by: Uwe Kleine-König <u.kleine-koenig@baylibre.com>
Link: https://patch.msgid.link/20250303114659.1672695-11-u.kleine-koenig@baylibre.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Uwe Kleine-König
2025-03-03 12:46:59 +01:00
committed by Jonathan Cameron
parent 9525c66de3
commit fb3a0811a7

View File

@@ -339,6 +339,7 @@ int ad_sd_calibrate(struct ad_sigma_delta *sigma_delta,
out:
sigma_delta->keep_cs_asserted = false;
ad_sigma_delta_set_mode(sigma_delta, AD_SD_MODE_IDLE);
ad_sigma_delta_disable_one(sigma_delta, channel);
sigma_delta->bus_locked = false;
spi_bus_unlock(sigma_delta->spi->controller);