iio: chemical: bme680: Fix measurement wait duration calculation

This function refers to the Bosch BME680 API as the source of the
calculation, but one of the constants does not match the Bosch
implementation. This appears to be a simple transposition of two digits,
resulting in a wait time that is too short. This can cause the following
'device measurement cycle incomplete' check to occasionally fail, returning
EBUSY to user space.

Adjust the constant to match the Bosch implementation and resolve the EBUSY
errors.

Fixes: 4241665e6e ("iio: chemical: bme680: Fix sensor data read operation")
Link: https://github.com/boschsensortec/BME68x_SensorAPI/blob/v4.4.8/bme68x.c#L521
Signed-off-by: Chris Spencer <spencercw@gmail.com>
Acked-by: Vasileios Amoiridis <vassilisamir@gmail.com>
Cc: stable@vger.kernel.org
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Chris Spencer
2026-02-05 14:55:45 +00:00
committed by Jonathan Cameron
parent 5187e03b81
commit f55b9510cd

View File

@@ -613,7 +613,7 @@ static int bme680_wait_for_eoc(struct bme680_data *data)
* + heater duration
*/
int wait_eoc_us = ((data->oversampling_temp + data->oversampling_press +
data->oversampling_humid) * 1936) + (477 * 4) +
data->oversampling_humid) * 1963) + (477 * 4) +
(477 * 5) + 1000 + (data->heater_dur * 1000);
fsleep(wait_eoc_us);