iio: adc: qcom-vadc-common: fix vadc_scale_fn_type kernel-doc

Fix multiple warnings in enum vadc_scale_fn_type by adding a leading
'@' to the kernel-doc descriptions.

Fixed 14 warnings in this one enum, such as:
Warning: include/linux/iio/adc/qcom-vadc-common.h:123 Enum value
 'SCALE_DEFAULT' not described in enum 'vadc_scale_fn_type'
Warning: ../include/linux/iio/adc/qcom-vadc-common.h:123 Enum value
 'SCALE_THERM_100K_PULLUP' not described in enum 'vadc_scale_fn_type'
Warning: ../include/linux/iio/adc/qcom-vadc-common.h:123 Enum value
 'SCALE_PMIC_THERM' not described in enum 'vadc_scale_fn_type'

Also prevent the warning on SCALE_HW_CALIB_INVALID by marking it
"private:" so that kernel-doc notation is not needed for it.

This leaves only one warning here, which I don't know the
appropriate description of:
qcom-vadc-common.h:125: warning: Enum value
 'SCALE_HW_CALIB_PMIC_THERM_PM7' not described in enum 'vadc_scale_fn_type'

Signed-off-by: Randy Dunlap <rdunlap@infradead.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Randy Dunlap
2025-10-17 00:07:27 -07:00
committed by Jonathan Cameron
parent 59795109fa
commit c5ebcc80fc

View File

@@ -83,27 +83,27 @@ struct vadc_linear_graph {
/**
* enum vadc_scale_fn_type - Scaling function to convert ADC code to
* physical scaled units for the channel.
* SCALE_DEFAULT: Default scaling to convert raw adc code to voltage (uV).
* SCALE_THERM_100K_PULLUP: Returns temperature in millidegC.
* @SCALE_DEFAULT: Default scaling to convert raw adc code to voltage (uV).
* @SCALE_THERM_100K_PULLUP: Returns temperature in millidegC.
* Uses a mapping table with 100K pullup.
* SCALE_PMIC_THERM: Returns result in milli degree's Centigrade.
* SCALE_XOTHERM: Returns XO thermistor voltage in millidegC.
* SCALE_PMI_CHG_TEMP: Conversion for PMI CHG temp
* SCALE_HW_CALIB_DEFAULT: Default scaling to convert raw adc code to
* @SCALE_PMIC_THERM: Returns result in milli degree's Centigrade.
* @SCALE_XOTHERM: Returns XO thermistor voltage in millidegC.
* @SCALE_PMI_CHG_TEMP: Conversion for PMI CHG temp
* @SCALE_HW_CALIB_DEFAULT: Default scaling to convert raw adc code to
* voltage (uV) with hardware applied offset/slope values to adc code.
* SCALE_HW_CALIB_THERM_100K_PULLUP: Returns temperature in millidegC using
* @SCALE_HW_CALIB_THERM_100K_PULLUP: Returns temperature in millidegC using
* lookup table. The hardware applies offset/slope to adc code.
* SCALE_HW_CALIB_XOTHERM: Returns XO thermistor voltage in millidegC using
* @SCALE_HW_CALIB_XOTHERM: Returns XO thermistor voltage in millidegC using
* 100k pullup. The hardware applies offset/slope to adc code.
* SCALE_HW_CALIB_THERM_100K_PU_PM7: Returns temperature in millidegC using
* @SCALE_HW_CALIB_THERM_100K_PU_PM7: Returns temperature in millidegC using
* lookup table for PMIC7. The hardware applies offset/slope to adc code.
* SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* @SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* The hardware applies offset/slope to adc code.
* SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* @SCALE_HW_CALIB_PMIC_THERM: Returns result in milli degree's Centigrade.
* The hardware applies offset/slope to adc code. This is for PMIC7.
* SCALE_HW_CALIB_PM5_CHG_TEMP: Returns result in millidegrees for PMIC5
* @SCALE_HW_CALIB_PM5_CHG_TEMP: Returns result in millidegrees for PMIC5
* charger temperature.
* SCALE_HW_CALIB_PM5_SMB_TEMP: Returns result in millidegrees for PMIC5
* @SCALE_HW_CALIB_PM5_SMB_TEMP: Returns result in millidegrees for PMIC5
* SMB1390 temperature.
*/
enum vadc_scale_fn_type {
@@ -120,6 +120,7 @@ enum vadc_scale_fn_type {
SCALE_HW_CALIB_PMIC_THERM_PM7,
SCALE_HW_CALIB_PM5_CHG_TEMP,
SCALE_HW_CALIB_PM5_SMB_TEMP,
/* private: */
SCALE_HW_CALIB_INVALID,
};