power: reset: sc27xx: Add platform_device_id table

Make the poweroff driver for SC27xx-series PMICs probe automatically.
Since the device representing the poweroff functionality of the SC27xx
PMIC is not supposed to have a dedicated device tree node without any
corresponding DT resources [1], an of_device_id table cannot be used
here. Instead, use a platform_device_id table to match the poweroff
sub-device instantiated by the parent MFD driver.

[1]: https://lore.kernel.org/all/20251002025344.GA2958334-robh@kernel.org/

Signed-off-by: Otto Pflüger <otto.pflueger@abscue.de>
Link: https://patch.msgid.link/20260528-sc27xx-mfd-cells-v3-2-25cd685d2743@abscue.de
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Otto Pflüger
2026-05-28 18:18:24 +02:00
committed by Sebastian Reichel
parent e3f669bed3
commit b6c7feeb60

View File

@@ -6,6 +6,7 @@
#include <linux/cpu.h>
#include <linux/kernel.h>
#include <linux/mod_devicetable.h>
#include <linux/module.h>
#include <linux/platform_device.h>
#include <linux/pm.h>
@@ -70,11 +71,18 @@ static int sc27xx_poweroff_probe(struct platform_device *pdev)
return 0;
}
static const struct platform_device_id sc27xx_poweroff_id_table[] = {
{ "sc2731-poweroff" },
{ }
};
MODULE_DEVICE_TABLE(platform, sc27xx_poweroff_id_table);
static struct platform_driver sc27xx_poweroff_driver = {
.probe = sc27xx_poweroff_probe,
.driver = {
.name = "sc27xx-poweroff",
},
.id_table = sc27xx_poweroff_id_table,
};
module_platform_driver(sc27xx_poweroff_driver);