hwmon: (pmbus/mp2975) Eliminate dead code

Coverity reports dead code in mp2975_data2reg_linear11(). Code analysis
shows that the parameter passed to the function is always non-negative.
This means that negative values do not need to be handled, and the
associated variable and conditional code can be removed.

No functional impact or change.

Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Guenter Roeck
2025-02-05 12:34:13 -08:00
parent bd300460ce
commit 9fcd738d13

View File

@@ -176,7 +176,6 @@ mp2975_vid2direct(int vrf, int val)
static u16 mp2975_data2reg_linear11(s64 val)
{
s16 exponent = 0, mantissa;
bool negative = false;
/* simple case */
if (val == 0)
@@ -196,10 +195,6 @@ static u16 mp2975_data2reg_linear11(s64 val)
/* Convert mantissa from milli-units to units */
mantissa = clamp_val(DIV_ROUND_CLOSEST_ULL(val, 1000), 0, 0x3ff);
/* restore sign */
if (negative)
mantissa = -mantissa;
/* Convert to 5 bit exponent, 11 bit mantissa */
return (mantissa & 0x7ff) | ((exponent << 11) & 0xf800);
}