drm/amd/display: Handle potential dpp_inst mismatch with pipe_idx

[Why]
In some pipe harvesting configs, we will select the incorrect
dpp_inst when programming DTO. This is because when any intermediate
pipe is fused, resource instances are no longer in 1:1
correspondence with pipe index.

[How]
When looping through pipes to program DTO, get the dpp_inst
associated with each pipe from res_pool.

Signed-off-by: Anthony Wang <anthony1.wang@amd.com>
Reviewed-by: Yongqiang Sun <yongqiang.sun@amd.com>
Acked-by: Stylon Wang <stylon.wang@amd.com>
Tested-by: Daniel Wheeler <daniel.wheeler@amd.com>
Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
Anthony Wang
2021-04-30 09:09:02 -04:00
committed by Alex Deucher
parent 98ad74c6a9
commit 9119e993cf

View File

@@ -106,10 +106,10 @@ static void rn_update_clocks_update_dpp_dto(struct clk_mgr_internal *clk_mgr,
for (i = 0; i < clk_mgr->base.ctx->dc->res_pool->pipe_count; i++) {
int dpp_inst, dppclk_khz, prev_dppclk_khz;
/* Loop index will match dpp->inst if resource exists,
* and we want to avoid dependency on dpp object
/* Loop index may not match dpp->inst if some pipes disabled,
* so select correct inst from res_pool
*/
dpp_inst = i;
dpp_inst = clk_mgr->base.ctx->dc->res_pool->dpps[i]->inst;
dppclk_khz = context->res_ctx.pipe_ctx[i].plane_res.bw.dppclk_khz;
prev_dppclk_khz = clk_mgr->dccg->pipe_dppclk_khz[i];