ARM: dts: exynos: Override thermal by label in Exynos4412 Odroids
Using full paths to extend or override a device tree node is error prone since if there was a typo error, a new node will be created instead of extending the node as it was desired. This will lead to run-time errors that could be hard to detect. A mistyped label on the other hand, will cause a dtc compile error (during build time). Signed-off-by: Krzysztof Kozlowski <krzk@kernel.org> Link: https://lore.kernel.org/r/20200830135200.24304-27-krzk@kernel.org
This commit is contained in:
@@ -66,25 +66,6 @@ xusbxti {
|
||||
clock-frequency = <24000000>;
|
||||
};
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
cpu_thermal: cpu-thermal {
|
||||
cooling-maps {
|
||||
cooling_map0: map0 {
|
||||
/* Corresponds to 800MHz at freq_table */
|
||||
cooling-device = <&cpu0 7 7>, <&cpu1 7 7>,
|
||||
<&cpu2 7 7>, <&cpu3 7 7>;
|
||||
};
|
||||
cooling_map1: map1 {
|
||||
/* Corresponds to 200MHz at freq_table */
|
||||
cooling-device = <&cpu0 13 13>,
|
||||
<&cpu1 13 13>,
|
||||
<&cpu2 13 13>,
|
||||
<&cpu3 13 13>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
&bus_dmc {
|
||||
@@ -174,6 +155,21 @@ opp-800000000 {
|
||||
};
|
||||
};
|
||||
|
||||
&cpu_thermal {
|
||||
cooling-maps {
|
||||
cooling_map0: map0 {
|
||||
/* Corresponds to 800MHz at freq_table */
|
||||
cooling-device = <&cpu0 7 7>, <&cpu1 7 7>,
|
||||
<&cpu2 7 7>, <&cpu3 7 7>;
|
||||
};
|
||||
cooling_map1: map1 {
|
||||
/* Corresponds to 200MHz at freq_table */
|
||||
cooling-device = <&cpu0 13 13>, <&cpu1 13 13>,
|
||||
<&cpu2 13 13>, <&cpu3 13 13>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
&pinctrl_1 {
|
||||
gpio_power_key: power_key {
|
||||
samsung,pins = "gpx1-3";
|
||||
|
||||
@@ -37,31 +37,6 @@ fan0: pwm-fan {
|
||||
#cooling-cells = <2>;
|
||||
cooling-levels = <0 102 170 230>;
|
||||
};
|
||||
|
||||
thermal-zones {
|
||||
cpu_thermal: cpu-thermal {
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert1>;
|
||||
cooling-device = <&cpu0 9 9>, <&cpu1 9 9>,
|
||||
<&cpu2 9 9>, <&cpu3 9 9>,
|
||||
<&fan0 1 2>;
|
||||
};
|
||||
map1 {
|
||||
trip = <&cpu_alert2>;
|
||||
cooling-device = <&cpu0 15 15>,
|
||||
<&cpu1 15 15>,
|
||||
<&cpu2 15 15>,
|
||||
<&cpu3 15 15>,
|
||||
<&fan0 2 3>;
|
||||
};
|
||||
map2 {
|
||||
trip = <&cpu_alert0>;
|
||||
cooling-device = <&fan0 0 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
&adc {
|
||||
@@ -76,6 +51,27 @@ &buck8_reg {
|
||||
regulator-max-microvolt = <3300000>;
|
||||
};
|
||||
|
||||
&cpu_thermal {
|
||||
cooling-maps {
|
||||
map0 {
|
||||
trip = <&cpu_alert1>;
|
||||
cooling-device = <&cpu0 9 9>, <&cpu1 9 9>,
|
||||
<&cpu2 9 9>, <&cpu3 9 9>,
|
||||
<&fan0 1 2>;
|
||||
};
|
||||
map1 {
|
||||
trip = <&cpu_alert2>;
|
||||
cooling-device = <&cpu0 15 15>, <&cpu1 15 15>,
|
||||
<&cpu2 15 15>, <&cpu3 15 15>,
|
||||
<&fan0 2 3>;
|
||||
};
|
||||
map2 {
|
||||
trip = <&cpu_alert0>;
|
||||
cooling-device = <&fan0 0 1>;
|
||||
};
|
||||
};
|
||||
};
|
||||
|
||||
&hdmicec {
|
||||
needs-hpd;
|
||||
};
|
||||
|
||||
Reference in New Issue