Although value 4 (INDOOR_SP_AP_OLD) is deprecated in IEEE standards, existing APs may still use this control value. Since this value is based on the old specification, we cannot trust such APs implement proper power controls. Therefore, move IEEE80211_6GHZ_CTRL_REG_INDOOR_SP_AP_OLD case from SP_AP to LPI_AP power type handling to prevent potential power limit violations. Signed-off-by: Pagadala Yesu Anjaneyulu <pagadala.yesu.anjaneyulu@intel.com> Reviewed-by: Johannes Berg <johannes.berg@intel.com> Signed-off-by: Miri Korenblit <miriam.rachel.korenblit@intel.com> Link: https://patch.msgid.link/20260111163601.6b5a36d3601e.I1704ee575fd25edb0d56f48a0a3169b44ef72ad0@changeid Signed-off-by: Johannes Berg <johannes.berg@intel.com>