mirror of
https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git
synced 2026-07-22 02:17:36 -04:00
In is_full_charged(), power_supply_get_by_name() is called to
obtain a reference to the fuel_gauge power supply. If the
voltage check (uV >= desc->fullbatt_uV) succeeds, the function
returns true directly without releasing the reference, leaking
the refcount.
Fix this by setting a flag and jumping to the out label where
power_supply_put() properly drops the reference.
Cc: stable@vger.kernel.org
Fixes: e132fc6bb8 ("power: supply: charger-manager: Make decisions focussed on battery status")
Signed-off-by: WenTao Liang <vulab@iscas.ac.cn>
Link: https://patch.msgid.link/20260611005322.53096-1-vulab@iscas.ac.cn
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>